: It strongly recommends using tools and crimp contacts from the same manufacturer to guarantee high-quality workmanship. Document Status & History
As of 2025, the current version is DIN EN 60352-2:2020-12 (published December 2020). It supersedes the 2006 edition. din en 60352-2 pdf
: Requirements for the crimp height, width, and visual characteristics (e.g., no cracked insulation, all wire strands captured). : It strongly recommends using tools and crimp
Back at the junction box, she replaced all six terminals on the BOP circuit, crimping each with religious precision. Then she used a (a spring scale) to verify each one. Finally, she applied a voltage drop test per Clause 5.2: 1 amp through the joint, measure millivolts across it. Result: 0.8 mV—well below the 5 mV limit. and visual characteristics (e.g.