Teqd-2301b Manual Link

The TEQD-2301B is an analog, 0–400°C temperature controller designed for CBS series continuous band sealers, often interchangeable with the NGE-2301B model. It operates via a manual rotary knob for setpoint adjustment and is compatible with 110V or 220V AC input voltages. For technical, installation, and operation details, you can refer to the NGE-2301B Operation Manual . Analog Temperature Controller TEQD-2301B (0-400C-220V)

Since the model number suggests an industrial or electronic device (e.g., a controller, analyzer, or power supply), this content is written as a generic, professional-grade operations and maintenance manual suitable for field engineers, lab technicians, or maintenance staff.

TEQD-2301B OPERATIONS & MAINTENANCE MANUAL Document Revision: 1.2 Compatible Firmware: v3.1x or higher Classification: General Use / Industrial

1. Introduction 1.1 Purpose This manual provides installation, operational, troubleshooting, and maintenance procedures for the Teqd-2301B [Insert Device Type, e.g., Multi-Channel Data Logger / PID Temperature Controller ]. It is intended for qualified technical personnel. 1.2 Key Features Teqd-2301b Manual

Dual 24-bit ADC inputs (channels A & B) Isolated 4-20mA output loop RS-485 Modbus RTU communication (default baud: 9600) User-configurable alarm relays (2x Form C) Front-panel membrane keypad with 128x64 graphical LCD

2. Safety Instructions | Symbol | Meaning | |--------|---------| | ⚠️ WARNING | Risk of electric shock or serious injury | | 🔥 HOT | Surface may exceed 60°C during operation | | ⚡ ESD | Sensitive electronics – use grounded wrist strap | WARNING: Disconnect all power sources before opening the Teqd-2301B enclosure. CAUTION: Do not exceed 30V DC on input terminals A+ / B+.

3. Installation 3.1 Mounting

Cutout dimensions: 92mm x 92mm (DIN 43700 standard) Panel thickness: 1.5 – 4.0 mm Clearance: Allow 50mm rear and 20mm side for ventilation

3.2 Terminal Block Wiring (Top View) | Terminal | Label | Function | |----------|-------|----------| | 1 | L (85–265V AC) | Power input phase | | 2 | N | Neutral | | 3 | ⏚ | Earth ground | | 4 | A+ | Sensor input channel A (+) | | 5 | A- | Sensor input channel A (-) | | 6 | B+ | Sensor input channel B (+) | | 7 | B- | Sensor input channel B (-) | | 8 | OUT+ | 4-20mA output (+) | | 9 | OUT- | 4-20mA output (–) | | 10 | COM | Relay common (Alarm 1) | | 11 | NO | Relay 1 N.O. | | 12 | COM | Relay common (Alarm 2) | | 13 | NO | Relay 2 N.O. | | 14 | D+ | RS-485 A / Data + | | 15 | D- | RS-485 B / Data - |

4. User Interface & Navigation 4.1 Front Panel Layout [LCD Display] [Menu] [Enter] [▲ Up] [▼ Down] [Alarm Reset] 4.2 Menu Structure It is intended for qualified technical personnel

Main Display → Live readings (Ch A / Ch B) Setup (hold Menu 3s) →

Input Config (Sensor type, range, units) Output Config (4-20mA scaling, retransmission source) Alarms (Setpoint, hysteresis, delay) Comm (Modbus address, baud, parity) System (Display contrast, restore defaults)